A-1 Appendix A Measurement Systems This appendix provides information regarding the measurement equipment used to perform this test/measurement program and block diagrams showing the interconnections of the various test set-ups. Table A-1 provides a list of the equipment used, including the manufacturer and model number, a brief description and where appropriate, the most recent manufacturer calibration date. Figures A-1 through A-4 illustrate the measurement equipment and related interconnections used to perform the tests and measurements described in this report. Figure A-5 shows the spectral characteristics of the filtered DTV signal that was placed on the adjacent channel(s) in the adjacent-channel interference tests. Table A-1. List of Measurement Equipment Equipment Quantity Manufacturer and Model Specifications Last Calibrated Spectrum Analyzer 1 Agilent E4448 PSA 3 Hz-50 GHz 03/13/08 Spectrum Analyzer 1 Agilent E7405A EMC 9 kHz – 26.5 GHz 05/08/08 Modulation Analyzer 1 Agilent 8901A - 09/14/07 Audio Analyzer 1 Agilent 8903B - 09/14/07 Signal Generator 1 Agilent E4437B ESG 250 kHz-4 GHz 05/02/08 Signal Generator 1 Agilent 4438C ESG 250 kHz – 6 GHz 07/03/08 Broadcast Test System 2 Rhode and Schwarz SFU w/ ATSC Signal Generator - WS-2100 RF Player 1 Wavetech, Inc. - - Step Attenuator 4 Agilent 8494B 0 to 11 dBDC – 18 GHz 08/14/07 09/17/07 12/05/07 12/06/07 Step Attenuator 3 Agilent 8495B 0 to 70 dBDC – 18 GHz 08/21/07 09/17/07 12/04/07 Step Attenuator 1 Agilent 8496B 0 to 110 dBDC – 18 GHz 12/05/07 TV Channel 29 Bandpass Filter 1 Micro Communications, Inc.; Interdigital Series 42100 560-566 MHz; 7-pole; 0.8-1.0 dB insertion loss; VSWR: 1.15 - Signal Combiner 2 MiniCircuits ZFSC-2-1W 50 ? - Log Periodic Antenna 1 A.R.A. LPB-2520/A 25 MHz – 2.0 GHz - Impedance Matching Transformer 1 Trilithic ZMT-57 75-50 ? - Low Noise Preamplifier 1 NardaNEL-0102N305-1MH 0.5 to 2 GHz - Vertical Ground Plane Antenna 1 FCC Lab 0 dBi 512 to 698 MHz 11/13/07 A-2 Figure A-1. “Clean” DTV Signal Measurement Equipment Configuration. Figure A-2. “Recorded” DTV Signal Measurement Equipment Configuration. WaveTech RF Player 50-75 ?Xformer WSD DUT 10-dB Steps 10-dB Steps 1-dB Steps WSD DUT 1-dB Steps 10-dB Steps SFU (DTV Signal Generator) A-3 Figure A-3. Adjacent Channel Interference Measurement Equipment Configuration. Figure A-4. Spurious Emission and EIRP Measurement Equipment Configuration. WaveTech RF Player 75-50 ?Xformer WSD - DUT 10-dB Steps 10-dB Steps 1-dB Steps DTV Signal Generator (SFU) BPF Spectrum Analyzer SignalCombiner SignalSplitter Spectrum Analyzer WSD DUT 3m mm A-4 Figure A-5. Filtered SFU Signal Compared to DTV Emissions Mask.